Author: lucrezia

THESIS EASY


It is a special device that controls the power delivery of the heating element, modulating it starting at 20% of output until 100% by acting on the rotation of the knob. In order to ensure safety for people, the device has an important element, which is a useful NTC sensor that prevents the ambient temperature from exceeding 37 ° C, in compliance with European legislation. It can be assembled with different heating elements, and its parts are easily obtained from our major European manufacturers and replaced. It is possible to select three preset schedules as indicated in the guide for activating the operating times:

1. Boost2h control: 2 hours of continuous heating at 100% capacity.
2. T24h control of the boost2h, to set it to happen automatically every day at the same time (2h on, 22hoff) (typically for morning shower).
3. T12h control of the boost2h, to set it to start automatically every 12 hours (2h on, 10h off, 2h on, 10hoff (typically morning and evening shower).

TECHNICAL SPECIFICATIONS

Technical specifications
Conformity marking

CE

Supply voltage

230 VAC – 50 Hz

Powers max

2000 W

Appliance classes Class I – Class II
IP code IP44
Size

113mm x 73mm x 39mm

Available colours White, Chrome

Continue reading

THESIS DUAL


Thesis Dual is a digital thermostat for the control of electric towel warmers that thanks to its two sensors is able to detect the temperature of the environment or that of the liquid inside the towel warmer. You can then use it as: a) Towel warmer thermostat: This function allows you to adjust the temperature of the towel warmer, regardless of the temperature of the room. b) Room thermostat: This function allows you to adjust the temperature of the room. The available functions are: 1. Anti-freeze: this function prevents the temperature from falling below 7°C.2. 2h timer: in this mode the heating element is activated and remains active for 2h, regardless of the ambient temperature or the internal temperature of the liquid. In order to ensure safety the external temperature cannot exceed 32 ° C and that of the liquid inside the towel warmer cannot exceed 70 ° C. At the end of 2h the thermostat returns to the mode that had been set previously. The 2h mode can be switched off at any time by pressing the ‘Mode’ button.

  1. The “Key Lock” function: This feature allows the user to lock the keyboard to prevent accidental changes.
  2. The “Night” function: This mode keeps the temperature close to the temperature set by the user. This mode can be used to heat the room to the desired temperature. Since the temperature of the NIGHT mode is always lower than the COMFORT temperature, it is recommended to use this mode to save energy during the night or when the room remains empty for 2 hours or more.
  3. “Wire-Pilot” mode: This is the mode in which the towel warmer is controlled from a remote-control panel. The operating mode will be selected by the Fil-Pilote control panel. The device also recognizes the most advanced six-order “Fil-Pilote” system that allows the use of the following functions:

◦ Standby: turns off the heating element, the thermostat remains on.
◦ Comfort: maintains the “Comfort” temperature set by the user.
◦ Eco: maintains the ambient temperature 3.5°C lower than the “Comfort” temperature.
◦ Anti-freeze: maintains the ambient temperature at 7°C.
◦ Comfort-1: Ambient temperature is maintained 1°C lower than “Comfort” temperature.
◦ Comfort-2: Ambient temperature is maintained 2°C lower than “Comfort” temperature.

TECHNICAL SPECIFICATIONS

Technical specifications
Conformity marking

CE

Supply voltage

230 VAC – 50 Hz

Range of supported powers

2000 W

Selectable temperature range 7°C ÷ 32°C
Appliance classes Class I – Class II
IP code IP44
Size 113mm x 73mm x 39mm
Available colours White, Chrome

Continue reading

DYNAMIC FLUID


It is the version of DYNAMIC that controls the fluid temperature.
Dynamic Fluyd is a special version with fluid temperature sensor, it allows regulation between 30°C and 70°C.

There are 4 temperature levels:
1: (30-40°)
2: (40-50°)
3: (50-60°)
4: (60-70°)

It is possible to set the duration of the selected temperature setpoint. The default duration is 1 hour and can be increased to 2, 3, 4 hours or continuous, which runs indefinitely.
CHRONO mode offers a separate programmable time for each day of the week.
Advanced settings are available, such as key lock.

TECHNICAL SPECIFICATIONS

Technical specifications
Conformity marking

CE

Supply voltage

230 VAC – 50 Hz

Powers

1500 W

Selectable temperature range 7°C ÷ 32°C
Appliance classes

Class I – Class II

IP code IP44
Size 71mm x 97,5mm x 47mm
Available colours White, Chrome

Continue reading

DYNAMIC


Possibility of right or left coupling of the towel warmer. It allows weekly programming with heat transfer to fluid and temperature control via the ambient sensor. It has a large display which is back lit and displays every status and mode of use that has been set. There is the possibility of rotating the entire towel warmer without removing the thermostat. It can be supplied with or without coupled resistance.

Available functions: 1. Heating device with heat transfer to fluid. 2. The ambient temperature is controlled by an external sensor. 3. The symmetry of the object allows both right and left coupling of the towel warmer. 4. The device can be controlled through the Galaxy IR remote control which is equipped with an accessory that makes it anchorable to the wall or to the towel warmer itself. 5. The “ECO” function reduces the set temperature by 3° in order to reduce energy consumption.

  1. The “Open window” function: The control is able to detect if a window has been opened by detecting a rapid drop in ambient temperature. If this happens, the radiator switches off for 30 minutes, after which the towel warmer will resume operation in the previously set state.
    7. The “Key Lock” function: This feature allows the user to lock the keyboard to avoid accidental changes.</br>
  2. The “Adaptive Starting Control – ASC” function: This function will turn on the heating element earlier than set (it can happen up to 2 hours earlier) to ensure that the room reaches the desired temperature at the set time. Note: The feature requires at least a couple of days of operation to achieve maximum efficiency. Note: The feature requires at least a couple of days of operation to reach maximum efficiency.</br>
  3. “Chrono” mode: This mode of operation allows the user to set a daily schedule to repeat weekly.
  4. “Fil-Pilot” mode: This is the mode in which the towel warmer is controlled from a remote-control panel. The operating mode will be selected by the Fil-Pilote control panel. The appliance also recognizes the most advanced six-order “Fil-Pilote” system that allows the use of the following functions:

◦ Standby: The heating element is turned off whilst the thermostat remains on.
◦ Comfort: The “Comfort” temperature is maintained as it was set by the user.
◦ Eco: The ambient temperature is maintained at 3.5°C lower than the “Comfort” temperature.
◦ Anti-freeze: The ambient temperature is maintained at 7°C.
◦ Comfort-1: The ambient temperature is maintained at 1°C lower than the “Comfort” temperature.
◦ Comfort-2: The ambient temperature is maintained at 2°C lower than the “Comfort” temperature.

NOTE: By activating this mode in versions without fil-pilots, the thermostat works in Comfort mode.

  1. The “Night” function: This mode keeps the temperature close to the temperature set by the user. This can be used to heat the room up to the desired temperature. Since the temperature of the NIGHT mode is always lower than the COMFORT temperature, it is recommended to use this mode to save energy at night or when the room remains empty for 2 hours or more.
  2. The “2 Hour Timer” function: In this mode, maximum power is supplied to the heating element for 120 minutes regardless of the ambient temperature. After the time has elapsed, the thermostat will return to the previously “stable” set operating mode before entering 2-HOUR TIMER mode.
    Note: A “stable” operating mode is a mode that has been operating for at least 5 seconds before switching to 2-hour TIMER mode.
    13. Anti-freeze: prevents the temperature from falling below 7°C.
  3. This digital programmable thermostat for electric towel warmers has the characteristic of being able to rotate 350 ° around the resistance. It is equipped with a resistance with a particular coupling produced HT SpA on which it is mechanically fixed.

TECHNICAL SPECIFICATIONS

Technical specifications
Conformity marking

CE

Supply voltage

230 VAC – 50 Hz

Range of supported powers

1500 W

Selectable temperature range 7°C ÷ 32°C ± 10%
Appliance classes

Class I – Class II

IP code IP44
Size 71mm x 97,5mm x 47mm
Available colours White, Chrome

Continue reading

SMART


Smart is an electronic thermostat for controlling electric towel warmers. This thermostat has an important function, since it detects the internal temperature of the towel warmer and, using a special heating element, keeps the towel warmer at the selected temperature. Twelve different types of resistors are available, already integrated in the electronic thermostat: from 100W to 1000W.

The operating modes of the Smart are: Comfort, Boost, Stand-by/Antifreeze, Timer12, Timer24. The upper LEDs indicate the temperature and the lower ones the set mode. Furthermore, if desired, it is possible to use the towel warmer in mixed water/electric operation, thanks to the special “T” joint.

TECHNICAL SPECIFICATIONS

Technical specifications
Conformity marking

CE

Supply voltage

230 VAC – 50 Hz

Range of supported powers

100 ÷ 1000 W

Operating fluid temperature 70°C ± 10%
Selectable temperature range 40°C ÷ 65°C (10°C automatically selected in antifreeze mode)
Maximum thermal fuse temperature 152°C
Appliance classes

Class I – Class II

IP code IP44
Size 56mm x 56mm x 44mm
Available colours White, Chrome

Continue reading

EVO


It is an electronic towel warmer thermostat which controls electric towel warmers. This thermostat detects the internal temperature of the towel warmer, then through a heating element it keeps the towel warmer at the selected temperature. Twelve different types of heating elements are available, already integrated into the electronic thermostat, with varying resitance: from 100W to 1000W.

TECHNICAL SPECIFICATIONS

Technical specifications
Operational modes

Comfort, Boost2h, Timer12h, Timer24h, Stand-by/Antifreeze, Key lock

Conformity marking

CE

Supply voltage

230 VAC – 50 Hz

Range of supported powers

100 ÷ 1000 W

Range of configurable fluid temperature

40°C ÷ 65°C (10°C automatically selected in
antifreeze mode)

Maximum thermal fuse temperature

152°C

Appliance classes

Class I – Class II

IP code IP44
Size

56mm x 56mm x 44mm

Available colours White, Chrome

TECHNICAL SPECIFICATIONS


Continue reading

SMART PROGRAM


Smart Program is an electronic programmable thermostat for electric towel warmers. Thanks to its internal sensor, it allows you to set the temperature of the towel warmer between 30 ° C and 70 ° C. Smart Program can only be controlled through its dedicated remote control, which can be hung thanks to its special support, which can be installed on the wall or directly on the towel warmer itself. Twelve different types of resistors are available: from 100W to 1000W, it can also be supplied in two colors: white or chrome. It can be installed, thanks to the special “T” joint in a towel warmer that provides the possibility of use in mixed operation.Heating device with heat transfer to fluid. 2. The temperature of the fluid is controlled by an internal sensor. 3. The symmetry of the object allows for both right and left coupling of the remote control on the towel warmer. 4. You can control the device through the Galaxy IR remote control which is equipped with an accessory that makes it anchorable to the wall or to the towel warmer.5. The “ECO” function is set at a 50° temperature for the internal liquid, to reduce energy consumption. 

6.The “Open window” function: The control is able to detect if a window has been opened by detecting a rapid drop in ambient temperature. If this happens, the radiator switches off for 30 minutes, after which the towel warmer will resume operation in the previously set state.

7. The “Key Lock” function: This feature allows the user to lock the keyboard to avoid accidental changes.

8. The “Adaptive Starting Control – ASC” function: This function will turn on the heating element earlier than set (it can happen up to 2 hours earlier) to ensure that the room reaches the desired temperature at the set time. Note: The feature requires at least a couple of days of operation to achieve maximum efficiency. Note: The feature requires at least a couple of days of operation to reach maximum efficiency.

9. “Chrono” mode: This mode of operation allows the user to set a daily schedule to repeat weekly.

10. “Fil-Pilot” mode: This is the mode in which the towel warmer is controlled from a remote-control panel. The operating mode will be selected by the Fil-Pilote control panel. The appliance also recognizes the most advanced six-order “Fil-Pilote” system that allows the use of the following functions:

◦ Standby: The heating element is turned off whilst the thermostat remains on.
◦ Comfort: The “Comfort” temperature is maintained as it was set by the user.
◦ Eco: The ambient temperature is maintained at 3.5°C lower than the “Comfort” temperature.
◦ Anti-freeze: The ambient temperature is maintained at 7°C.
◦ Comfort-1: The ambient temperature is maintained at 1°C lower than the “Comfort” temperature.
◦ Comfort-2: The ambient temperature is maintained at 2°C lower than the “Comfort” temperature.

NOTE: By activating this mode in versions without fil-pilots, the thermostat automatically works in Comfort mode.

TECHNICAL SPECIFICATIONS

Technical specifications
Operational modes

Comfort, Night, Antifreeze (7°C) Stand-by, Chrono, Boost 2h, ECO, Fil-Pilote (for Class II version only), Open window detection

Conformity marking

CE

Supply voltage

230 VAC – 50 Hz

Supported power range

100 ÷ 1000 W

Selectable temperature range 10°C ÷ 32°C
Maximum thermal fuse temperature 152°C
Appliance classes Class I – Class II
IP code IP44
Size 56mm x 56mm x 44mm
Available colours White, Chrome

Continue reading

SMART ECO


It is an electronic control for electric towel warmers. Twelve different types of resistors are available: from 100W to 1000W.

1. Heating device with heat transfer from liquid.
2. The fluid temperature is kept constant and is controlled by an internal sensor.
3. The symmetry of the object allows both right and left coupling of the towel warmer.
4. You can choose between 3 different schedules  by means of the dedicated button, as indicated in the timer setting guide.
5. It is possible to activate the stand-by function by using the dedicated button and its activation is confirmed by a red LED.
6. The set program and the operating phases are visible from the indicator LED positioned at the bottom.
7. You can use the towel warmer in mixed operation thanks to the special “T” joint.

TECHNICAL SPECIFICATIONS

Technical specifications
Operational modes

Boost2h, Timer12h, Timer24h, Stand-by/Antifreeze

Conformity marking

CE

Supply voltage

230 VAC – 50 Hz

Range of supported powers 100 ÷ 1000 W
Operating Fluid temperature 70°C ± 10%
Maximum thermal fuse temperature 152°C
Appliance classes Class I – Class II
IP code IP44
Size 56mm x 56mm x 44mm
Available colours White, Chrome

Continue reading

NANO


Device with ON/OFF switch for electric towel warmers with fluid heat transfer. The switch lights up when on the ON position in order to indicate the state of supply of electricity to the heating element. In order to function it requires the connection to the elctrical grid by means of a sectioning device. The symmetry of the product allows coupling of both the left and the right side of the towel warmer.

1. Heating device with heat transfer from liquid.
2. Fluid temperature kept constant at 70° thanks to an internal sensor.
3. The symmetry of the object allows both right and left coupling of the towel warmer.
4. Light switch indicates that the device is heating the fluid.
5. Nice aesthetics.
6. Available in white as well as in chrome color.

TECHNICAL SPECIFICATIONS

Technical specifications
Conformity marking

CE

Supply voltage

230 VAC – 50 Hz

Maximun power

2000 W

Operating Fluid temperature 7°C ÷ 32°C
Appliance classes Class I – Class II
IP code IPX4
Size 36mm x 96mm
Available colours White, Chrome

Continue reading

PAD


PAD

Heating element for electric towel warmers with fluid heat transfer. It provides constant temperature control via sensor that is placed inside the heating element. It must be connected to a protected mains by means of a sectioning device. The symmetry of the product allows for the coupling of the towel warmer both on the right and the left side. The display allows for the visualization of the power supply through a blue light ring with a rather pleasing esthetic effect.
1. Heating device with heat transfer from liquid.
2. Fluid temperature kept constant at 70° thanks to an internal sensor.
3. The symmetry of the object allows both right and left coupling of the towel warmer.
4. Light ring indicates whether the device is attached to a power source.
5. The towel warmer thermostat is aesthetically pleasing.
6. Available in white as well as in chrome color.

TECHNICAL SPECIFICATIONS

Technical specifications
Conformity marking

CE

Supply voltage

230 VAC – 50 Hz

Support power range

100 ± 1000 W

Operating Fluid temperature

70°C ± 10%

Maximum thermal fuse temperature 152°C
Appliance classes Class I
IP code IPX5
Size Diameter 28,5mm – Plastic cylinder 45,0mm
Available colours White, Chrome

Continue reading