Infinity is a chrono-thermostat for the control of electric radiators, the internal resistance of the radiator is controlled by a triac with PID control. This system allows for better regulation of the temperature thus always keeping the environment comfortable, thus leading to energy savings. All functions can be set remotely via Wi-Fi or radio. In addition to the basic functions of a chrono thermostat, the following functions are available: Open window detection that deactivates the radiator when the room window is opened thus avoiding wasting energy unnecessarily The child protection function that lowers the surface temperature of the radiator The Radar function that is activated if the room is empty, ECO mode which brings a reduction in consumption The ASC function that anticipates the time of switching on the thermostat so that the environment is at the desired temperature at the time set in one of the three programs of the Chrono mode.
In addition to the basic functions, this version is equipped with:
• Triac switching.
• LCD backlight.
• IR receiver (Works with Galaxy IR).
In addition to the basic functions, this version is equipped with:
• Wi-Fi (compatible with Domus One App).
• Compatible with Voice control (Alexa and Google Home).
• Triac switching.
• LCD backlight.
• Backlit button.
Available functions:
1. Heating device with heat transfer to fluid.
2. The ambient temperature is controlled by an external sensor.
3. The symmetry of the object allows both right and left coupling of the towel warmer.
4. You can control the device through the Galaxy IR remote control which is equipped with an accessory that makes it anchorable to the wall or to the towel warmer.
5. The “ECO” function reduces the set temperature by 3° to reduce energy consumption.
6. The “Open window” function: The control is able to detect if a window has been opened by detecting a rapid drop in ambient temperature. If this happens, the radiator switches off for 30 minutes, after which the towel warmer will resume operation in the previously set state.
7. The “Key Lock” function: This feature allows the user to lock the keyboard so as to avoid accidental changes.
8. The “Adaptive Starting Control – ASC” function: This function will turn on the heating element earlier than planned (for up to 2 hours) to ensure that the room reaches the desired temperature at the set time. Note: The feature requires at least a couple of days of operation for maximum efficiency.
9. “Chrono” mode: This mode of operation allows the user to set a weekly repeating daily schedule.
10. “Fil-Pilot” mode: This is the mode in which the towel warmer is controlled from a remote-control panel. The operating mode will be selected by the Fil-Pilote control panel. The radiator thermostat also recognizes the most advanced six-order “Fil-Pilote” system that allows the use of the following functions:
◦ Standby: The thermostat remains on whilst the heating element is switched off.
◦ Comfort: The “Comfort” temperature is maintained as set by the user. ◦ Eco: The ambient temperature is maintained 3°C lower than the “Comfort” temperature.
◦ Anti-freeze: The ambient temperature is maintained at 7°C. ◦ Comfort-1: The ambient temperature is maintained 1°C lower than the ” Comfort” temperature.
◦ Comfort-2: The ambient temperature is maintained 2°C lower than “Comfort” temperature. NOTE: By activating this mode in versions without fil-pilots the thermostat works in Comfort mode. 11. The “Night” function: This mode keeps the temperature close to the temperature set by the user. Use this mode to heat the room to the desired temperature. Since the temperature of the NIGHT mode is always lower than the COMFORT temperature, it is recommended to use this mode to save energy at night or when the room remains empty for 2 hours or more. 12. The “2 Hour Timer” function: In this mode, maximum power is supplied to the heating element for 120 minutes regardless of the ambient temperature. After the time has elapsed, the thermostat will return to the previously set “stable” operating mode before entering 2-HOUR TIMER mode.
Note: A “stable” operating mode is a mode that has been operating for at least 5 seconds before switching to TIMER mode 2 HOURS 13. Anti-freeze: The temperature is prevented from falling below 7°C.
14. Behavioral indicator.
15. Relay switches.
Technical specifications | |
---|---|
Operational modes | Comfort, Night, Fil-Pilote, Timer2h or Boost2h, Stand-by, Clock-thermostat, Antifreeze, |
Conformity marking | CE |
Supply voltage | 230 VAC – 50 Hz |
Range of controllable powers | Up to 2000 W |
Ambient working temperature | 10°C ÷ 32°C |
Appliance classes | Class I |
IP code | IP24 |
Size | 190mm x 83mm x 64mm |
Available colours | White, Noir Sablè |